To establish the connection, perform the following steps at the processor end:

1.Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600 card in the host processor or UIP.

2.Connect the other end of the 035-0153-0031 cable to the 002-0039-0031 connector.

3.Connect the 002-0039-0031 connector to one of the local DCE devices.

Perform the following steps at the remote end:

1.Connect the grounded end of the 035-0152-0031 cable to the TERM IN port on the SRCU.

2.Connect the other end of the 035-0152-0031 cable to the 002-0032-0031 connector.

3.Connect the 002-0032-0031 to the null modem connector.

4.Connect the null modem connector to the remote DCE device.

See Appendix A, Modem Settings, for further information on optioning 3810, 3811, 3820, or 2224CEO modems for this application.

Connecting a Local DCX Multiplexer

To connect a local 840/850 DCX multiplexer, you will need the following materials:

035-0153-0031 cable

002-0040-0031 connector

To establish the connection, perform the following steps:

1.Connect the grounded end of the 035-0153-0031 cable to an available port on the IPC-1600 card in the host processor or UIP.

2.Connect the other end of the 035-0153-0031 cable to the 002-0040-0031 connector.

3.Connect the 002-0040-0031 connector to the MIU attached to the DCX multiplexer.

Connecting a Remote DCX Multiplexer

To connect a remote DCX multiplexer, you will need the following materials:

035-0153-0031 cable

002-0039-0031 connector