COMSPHERE 6800 Series Network Management System

NOTE

The memory module can be installed in two possible ways. The correct way does not interfere with either the metal bracket on the board or any other memory module. If you have any such contact between modules or with the metal bracket, gently remove the module, reverse it and reinstall.

3.Slide the memory board into the slot from which it came ensuring that the board's connectors are firmly seated in the bus slots.

4.Using the saved screw, reattach the memory board's metal bracket to the chassis.

Preinstallation Steps for the IPC-1600 Card on the System 15000

To configure the IPC-1600 card, refer to Figure 2-14 and perform the following steps:

1.On the bank labeled DS2, set the IRQ to 11 with switches 1 through 8.

2.On the bank labeled DS1, set the I/O address to 110 with switches 9 through 11.

3.On the bank labeled DS1, set the memory address to F00000 (see Table 2-6) with switches 1 through 8.

Table 2-6

IPC-1600 Ð Memory Switch Settings (DSI)

Switches

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

X

X

X

X

 

 

 

 

 

 

 

 

 

OFF

X

X

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

2-40

January 1997

6800-A2-GN22-30

Page 63
Image 63
Paradyne 6800 Preinstallation Steps for the IPC-1600 Card on the System, IPC-1600 Ð Memory Switch Settings DSI Switches