Paradyne 6800 manual Connecting the Earlier Version 719 Networker

Models: 6800

1 351
Download 351 pages 51.03 Kb
Page 138
Image 138

COMSPHERE 6800 Series Network Management System

To connect a 719 NETWORKER to the host processor, perform the following steps:

1.Connect the 035-0153-0031 cable to the IPC-1600 port that is configured as the external systems port.

2.Connect the 002-0021-0031 connector to the 035-0153-0031 cable.

3.Connect the 002-0021-0031 connector to any unused data channel port on the 719 NETWORKER.

Connecting an Event or Command Port

To connect an event port or command port on the 719 NETWORKER to the host processor, you will need the following materials:

Two 035-0153-0031 cables

Two 002-0021-0031 connectors

To establish the connection perform the following steps:

1.Connect 035-0153-0031 to the IPC-1600 port that is configured as the event or command port.

2.Connect 002-0021-0031 to 035-0153-0031.

3.Connect the 002-0021-0031 to an unused data channel port on the 719 NETWORKER.

Connecting the Earlier Version 719 NETWORKER

To connect the pre-3.K version of the 719 NETWORKER, the following materials are required.

Two 035-0153-0031 cables

002-0039-0031 connector

002-0021-0031 connector

To connect the 719 NETWORKER to the host processor, perform the following steps.

1.Connect one end of the 035-0153-0031 cable to the IPC-1600 port that is configured as the event port.

2.Connect the other end of the 035-0153-0031 cable to the 002-0021-0031 connector.

3.Connect the 002-0021-0031 connector to any unused data channel port on the 719

NETWORKER.

4.Connect one end of the other 035-0153-0031 cable to the IPC-1600 port that is configured as the external systems port.

5.Connect the other end of the 035-0153-0031 cable to a 002-0039-0031 connector.

6.Connect the 002-0039-0031 connector to an unused data channel port on the 719

NETWORKER.

4-34

January 1997

6800-A2-GN22-30

Page 138
Image 138
Paradyne 6800 manual Connecting the Earlier Version 719 Networker