Other Relevant Precautions (cont’d)

Third Party’s Application Programs

Do not install a third party’s application programs into the PC of the equipment. Those application programs can be responsible for display of unexpected windows, adverse effects on the equipment, and interference in the operation of the system program. Hitachi shall not be liable for the troubles caused by such application programs.

Protection against Computer Viruses

Computer viruses are malicious programs that sneak into the PC to cause misbehavior or damage to data. And, a program designed to offer protection against and eradicate computer viruses is called a vaccine program.

Virus infection can be caused by using a floppy disk or other storage medium infected by a virus. Note also that once the PC is infected by a virus, it may spread to other computers through storage medium. Therefore, never use a program or storage medium that is suspected of containing a virus.

If there is a possibility of virus infection, check for a virus using a vaccine program. The user is requested to prepare a proper vaccine program and carry out virus removal on his or her own responsibility.

Note, however, that some kinds of vaccine programs may cause incorrect operation of the S-4800 control program. If a problem occurs after you install a vaccine program, remove it or execute virus check when the S-4800 program is not running. It is desirable not to set the vaccine program in the auto start-up group, or to terminate the vaccine program before starting the S-4800 program.

Do Not Change Computer Settings

Do not change the following system settings of your PC. These are set up at the optimum conditions for operation of the S-4800 SEM before shipping.

(a)Connection to the USB ports

This instrument uses a USB port for communication between the PC and the internal microprocessor. The USB port number 1 is occupied for the instrument. Use USB ports on the installed additional USB board for external storage devices, printer etc. Do not connect these units to the standard USB ports of PC even if these are open.

(b)Display screen setting

Display properties need to be set at 1280x1024 pixels for the desktop area, true color (24 bit) mode and 60Hz to 70Hz for the refresh rate. Using other resolution, faster refresh rate or 256 color mode may cause an abnormal screen display.

(c)Sub programs

This instrument operates using many of dll programs along with control program. Deletion of files in the Windows directory or change of the registry will cause troubles. Also do not delete tasks and processes using the task manager.