6.7 Test operation

6. SERVO CONFIGURATION SOFTWARE

6.7 Test operation

The test operation mode is designed to confirm servo operation and not to confirm

machine operation. In this mode, do not use the servo motor with the machine. CAUTION Always use the servo motor alone.

If any operational fault has occurred, stop operation using the forced stop (EMG).

6.7.1 Jog operation

POINT

In the jog operation mode, do not rewrite data from the point table list screen or the servo amplifier's front panel. Otherwise, the set values are made invalid.

The servo motor will not operate if the forced stop (EMG), forward rotation stroke end (LSP) and reverse rotation stroke end (LSN) are off. Make automatic ON setting to turn on these devices or make device setting to assign them as external input signals and turn off across these signals and SG. (Refer to Section 6.6.)

Hold down the “Forward” or “Reverse” button to rotate the servo motor. Release the “Forward” or “Reverse” button to stop.

Click “Test” on the menu bar and choose “Jog” on the menu.

When the above choices are made, the following window appears:

a)

c)

b)

d)

e)

f)

6 - 15