(4)Connection of the regenerative brake option

14.OPTIONS AND AUXILIARY EQUIPMENT

(4)Connection of the regenerative brake option

The regenerative brake option will generate heat of about 100Manual backgroundManual background. Fully examine heat dissipation, installation position, used cables, etc. before installing the option. For wiring, use flame-resistant cables and keep them clear of the regenerative brake option body. Always use twisted cables of max. 5m(16.4ft) length for connection with the servo amplifier.

(a)MR-J2S-350CL or less

Always remove the wiring from across P-D and fit the regenerative brake option across P-C.

The G3 and G4 terminals act as a thermal protector. G3-G4 are disconnected when the regenerative brake option overheats abnormally.

Servo amplifier

DManual backgroundManual background

Always remove the lead from across P-D.

Regenerative brake option

PManual backgroundManual background CManual background

(Note2)

5m (16.4 ft) max.

P

C

G3

G4

Fan (Note 1)

Note: 1. When using the MR-RB50, forcibly cool it with a cooling fan (1.0m3/min,Manual background92 or so).

2.Make up a sequence which will switch off the magnetic contactor (MC) when abnormal heating occurs.

G3-G4 contact specifications Maximum voltage: 120V AC/DC Maximum current: 0.5A/4.8VDC Maximum capacity: 2.4VA

For the MR-RB50 install the cooling fan as shown.

Manual background Top

Fan

Terminal block

Thermal relay

 

 

Bottom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal installation Installation surface

Vertical

installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Unit : mm(in)] Fan installation screw hole dimensions

2-M3 screw hole (for fan installation) Depth 10 or less (Screw hole already

machined)

82.5

(3.25)

133

(5.24)

82.540 (1.58)

(3.25)

Recommended fan:

Toyo Denki's TL396A or equivalent