(2) MR-J2S-200CL MR-J2S-350CL

1. FUNCTIONS AND CONFIGURATION

(2) MR-J2S-200CL MR-J2S-350CL

POINT

This servo amplifier is shown without the front cover. For removal of the front cover, refer to Section 1.6.2.

 

 

Name/Application

Reference

 

 

 

 

 

Battery holder

 

Section4.5

 

Contains the battery for absolute position data backup.

 

 

 

 

 

Battery connector (CON1)

 

Section4.5

 

Used to connect the battery for absolute position data

 

backup.

 

 

 

 

 

 

 

 

 

Display

 

 

Chapter7

 

The 5-digit, seven-segment LED shows the servo

 

status and alarm number.

 

 

 

 

 

 

 

Operation section

 

 

 

Used to perform status display, diagnostic, alarm and

 

MODE UP DOWN SET

parameter setting operations.

 

 

MODE

UP DOWN

SET

 

 

 

 

Used to set data.

Chapter7

Used to change the display or data in each mode.

 

Used to change the

 

 

mode.

 

 

 

 

 

 

 

 

 

I/O signal connector (CN1A)

Section3.3

 

Used to connect digital I/O signals.

 

 

 

 

 

 

 

 

 

 

I/O signal connector (CN1B)

Section3.3

 

Used to connect digital I/O signals.

 

 

 

 

 

 

 

 

 

 

Communication connector (CN3)

Chapter6

 

Used to connect a command device (RS-422/RS232C)

Chapter15

 

and output analog monitor data.

Section14.1.4

 

 

 

 

 

 

 

 

Name plate

Section1.4

 

 

 

 

 

 

 

 

Charge lamp

 

 

Lit to indicate that the main circuit is charged. While

 

 

this lamp is lit, do not reconnect the cables.

 

 

 

 

 

 

 

 

 

Encoder connector (CN2)

Section3.3

 

Connector for connection of the servo motor encoder.

Section14.1.4

 

 

 

 

 

 

 

 

Main circuit terminal block (TE1)

Section3.7

 

Used to connect the input power supply and servo

 

motor.

 

 

 

 

 

 

 

 

 

Control circuit terminal block (TE2)

Section3.7.2

 

Used to connect the control circuit power supply and

 

Section14.1.1

 

regenerative brake option.

 

 

Cooling fan

 

 

 

 

 

 

Protective earth (PE) terminal (

 

 

 

)

Section3.10

 

 

 

 

Ground terminal.

Mounting hole (4 places)

 

 

 

 

 

 

 

1 - 15