7.5.2 Operation example

7. DISPLAY AND OPERATION

7.5.2 Operation example

(1)Parameter of 5 or less digits

The following example shows the operation procedure performed after power-on to change the home position setting method (Parameter No.8) into the data setting type. Press the "MODE" button to switch to the basic parameter screen.

Press MODE four times. Select parameter No.8 withUP or DOWN.

The parameter number is displayed.

Press UP or DOWN to change the number.

Press SET twice.

The set value of the specified parameter number flickers.

Press UP twice.

During flickering, the set value can be changed.

Use UP or DOWN .

((1)Parameter of 5 or less digitsManual backgroundManual background 2: Data setting type)

Press SET to enter.

To shift to the next parameter, press the "UP" or "DOWN" button.

When changing the parameter No.8 (home position return type) setting, change its set value, then switch power off once and switch it on again to make the new value valid.