3.7 Input power supply circuit

3. SIGNALS AND WIRING

3.7 Input power supply circuit

When the servo amplifier has become faulty, switch power off on the servo amplifier power side. Continuous flow of a large current may cause a fire.

CAUTION Use the trouble signal to switch power off. Otherwise, a regenerative brake transistor fault or the like may overheat the regenerative brake resistor, causing a fire.

3.7.1 Connection example

Wire the power supply and main circuit as shown below so that the servo-on (SON) turns off as soon as alarm occurrence is detected and power is shut off.

A no-fuse breaker (NFB) must be used with the input cables of the power supply.

(1) For 3-phase 200 to 230VAC power supply

Forced

OFF

ON

RA stop

 

 

 

MC

 

 

MC

 

 

SK

NFBMC

Servo amplifier

Manual background L1 3-phaseManual backgroundManual background

200 to 230 VACManual background L2 Manual background L3

Manual background L11

Manual background L21

Forced stop Servo-on

EMG

SON

SG

VDD

COM

ALM

RA

Trouble

3 - 23