Mitsubishi Electronics MR-J2S- CL specifications MR-J2S-700CL POINT, Functions And Configuration

Models: MR-J2S- CL

1 337
Download 337 pages 389 b
Page 36
Image 36
(4) MR-J2S-700CL

1. FUNCTIONS AND CONFIGURATION

(4) MR-J2S-700CL

POINT

The servo amplifier is shown without the front cover. For removal of the front cover, refer to next page.

MODE UP DOWN SET

Cooling fanManual background

Installation notch (4 places)

Name/Application

Reference

Battery connector (CON1)

 

Used to connect the battery for absolute position data

Section4.5

backup.

 

 

 

 

 

 

 

Battery holder

Section4.5

Contains the battery for absolute position data backup.

 

Display

 

The 5-digit, seven-segment LED shows the servo

Chapter7

status and alarm number.

 

 

 

 

 

 

 

Operation section

 

Used to perform status display, diagnostic, alarm and

 

parameter setting operations.

 

MODE UP DOWN SET

 

Used to set data.

Chapter7

 

 

 

 

 

Used to change the

 

display or data in each

 

mode.

 

Used to change the

 

mode.

 

I/O signal connector (CN1A)

Section3.3

Used to connect digital I/O signals.

 

 

 

 

 

 

 

I/O signal connector (CN1B)

Section3.3

Used to connect digital I/O signals.

 

 

 

 

 

 

 

Communication connector (CN3)

Chapter6

Used to connect a command device (RS-422/RS232C)

Chapter15

and output analog monitor data.

Section14.1.4

 

 

 

 

 

 

Charge lamp

 

Lit to indicate that the main circuit is charged.

 

While this lamp is lit, do not reconnect the cables.

 

 

 

 

 

 

 

Control circuit terminal block (TE2)

Section3.7.2

Used to connect the control circuit power supply.

Section14.1.4

 

 

 

 

 

 

Encoder connector (CN2)

Section3.3

Connector for connection of the servo motor encoder.

Section14.1.4

 

 

 

 

 

 

Name plate

Section1.3

 

 

 

 

 

 

Main circuit terminal block (TE1)

Section3.7.2

Used to connect the input power supply, regenerative

Section12.1

brake option and servo motor.

Section14.1.1

 

 

 

 

 

 

Protective earth (PE) terminal (

 

 

 

)

Section3.10

 

 

 

Ground terminal.

Section12.1

 

 

 

 

 

 

1 - 17

Page 36
Image 36
Mitsubishi Electronics MR-J2S- CL specifications MR-J2S-700CL POINT, Functions And Configuration