Mitsubishi Electronics MR-J2S- CL Diagnosis mode list, Display And Operation, Name, Description

Models: MR-J2S- CL

1 337
Download 337 pages 389 b
Page 189
Image 189
7.3.2 Diagnosis mode list

7. DISPLAY AND OPERATION

7.3.2 Diagnosis mode list

Name

Display

Description

 

 

 

Not ready.

 

 

 

Indicates that the servo amplifier is being initialized or an alarm

 

 

 

has occurred.

Sequence

 

 

Ready.

 

 

 

 

 

 

Indicates that the servo was switched on after completion of

 

 

 

initialization and the servo amplifier is ready to operate.

 

 

 

Indicates the ON-OFF states of the external I/O signals.

 

 

 

The upper segments correspond to the input signals and the

External I/O signal

 

lower segments to the output signals.

Refer to section 7.6.

Lit: ON

display

 

 

 

Extinguished: OFF

 

 

 

 

 

 

The I/O signals can be changed using the servo configuration

 

 

 

software.

 

 

 

The digital output signal can be forced on/off. (Refer to Section

Output signal (DO)

 

7.7)

forced output

 

 

 

 

 

Jog operation can be performed when there is no command from

 

Jog feed

 

the external command device. (Refer to Section 7.8.2)

 

 

 

 

 

 

The servo configuration software (MRZJW3-SETUP151E) is

 

Positioning

 

required for positioning operation. This operation cannot be

 

 

performed from the operation section of the servo amplifier.

 

operation

 

Test

 

Positioning operation can be performed once when there is no

 

 

operation

 

 

command from the external command device.

mode

Motorless

 

Without connection of the servo motor, the servo amplifier

 

 

provides output signals and displays the status as if the servo

 

operation

 

motor is running actually in response to the external input

 

 

 

signal. (Refer to Section 7.9.4)

 

Machine

 

Merely connecting the servo amplifier allows the resonance point

 

 

of the mechanical system to be measured.

 

analyzer

 

 

 

The servo configuration software (MRZJW3-SETUP151E or later)

 

operation

 

 

 

is required for machine analyzer operation.

 

 

 

 

 

 

Indicates the version of the software.

Software version Low

 

 

 

 

 

Indicates the system number of the software.

Software version High

 

 

 

 

 

Maker setting screen. Do not perform operation on this screen.

For manufacturer

 

 

setting

 

 

 

7 - 6