Mitsubishi Electronics MR-J2S- CL Status display 1Status display data read, Command, Data No, 15

Models: MR-J2S- CL

1 337
Download 337 pages 389 b
Page 315
Image 315
15.12.2 Status display

15. COMMUNICATION FUNCTIONS

15.12.2 Status display

(1)Status display data read

When the master station transmits the data No. to the slave station, the slave station sends back the data value and data processing information.

(a)Transmission

Transmit command [0][1] and the data No. corresponding to the status display item to be read. Refer to Section 15.11.1.

(b)Reply

The slave station sends back the status display data requested.

0 0

Data 32 bits long (represented in hexadecimal) (Data conversion into display type is required)

Display type

0:Used unchanged in hexadecimal

1:Conversion into decimal required

Decimal point position 0: No decimal point

1: Lower first digit (usually not used)

2: Lower second digit

3: Lower third digit

4: Lower fourth digit

5: Lower fifth digit

6: Lower sixth digit

(2) Status display data clear

The cumulative feedback pulse data of the status display is cleared. Send this command immediately after reading the status display item. The data of the status display item transmitted is cleared to zero.

Command

Data No.

Data

[8][1]

[0][0]

1EA5

For example, after sending command [0][1] and data No. [8][0] and receiving the status display data, send command [8][1], data No. [0][0] and data [1EA5] to clear the cumulative feedback pulse value to zero.

15 - 18

Page 315
Image 315
Mitsubishi Electronics MR-J2S- CL Status display 1Status display data read, Status display data clear, Command, Data No