EOnCE Module Internal Architecture

4.5.3.3 Optional External Event Detection Address Channels

The EDU has two ports to optional external event detection channels named EDCA6 and EDCA7. If needed, the system designer may add additional event detection capabilities to the EOnCE using these ports. These outcomes of EDCA6/7 events could include the following:

Placing the core in debug state

Generating a core debug exception

Enabling the trace logic

Disabling the trace logic

Generating a counter event

Combinations with other events in the event selector

Setting the debug reason bits in ESR and the event status bits in EMCR EDCA6 and EDCA7 do not have an EE pin associated with them.

4.5.4Event Selector (ES)

The ES selects the source for various debugging operations. The possible sources that can be selected are:

Outputs of EDCA instances

Outputs of optional external EDCA events

Output of the EDCD

Output of the event counter

EE signals

DEBUGEV instruction

Each of these source events could be programmed1 in the event selector to cause some or all of the following actions:

Entry into Debug state

Execution of a Debug exception

Enable or disable program tracing

1. They can be programmed individually or combined with other simultaneous events

SC140 DSP Core Reference Manual

4-25

Page 135