CONT

Instruction Formats and Opcodes

Instruction

Words

Cycles1

Type

Opcode

 

 

 

 

 

 

 

 

15

 

 

8

7

0

CONT label

2

3/4

4

 

 

 

 

 

 

0

0

1

0 0 0 1 1

A A A 0 0 0

1 1

 

 

 

 

1

0

0

A A A A A

A A A A A A A a

 

 

 

 

 

 

 

 

 

 

Note 1: If LC > 1, CONT uses 3 cycles. If LC ≤ 1, CONT uses 4 cycles.

Instruction Fields

displacement

aAAAAAAAAAAAAAAA0

16-bit signed PC relative displacement. The

 

 

encoding is the displacement with bit 0

 

 

stripped and replaced by the sign bit.

A-134