Intel 8XC196NP, 80C196NU, Microcontroller manual External RC Circuit

Models: Microcontroller 80C196NU 8XC196NP

1 471
Download 471 pages 22.3 Kb
Page 250
Image 250

SPECIAL OPERATING MODES

XTAL1

CLKOUT

PH1

Internal Powerdown

Signal

EXTINTx

RPD

Timeout (Internal)

A3159-01

Figure 12-3. Power-up and Powerdown Sequence When Using an External Interrupt

When using an external interrupt signal to exit powerdown mode, we recommend that you con- nect the external component shown in Figure 12-4 to the RPD pin. The discharging of the capac- itor causes a delay that allows the oscillator and phase-locked loop circuitry to stabilize before the internal CPU and peripheral clocks are enabled.

MCS®96

Microcontroller

RPD

C1

A2389-02

Figure 12-4. External RC Circuit

12-9

Page 250
Image 250
Intel 8XC196NP, 80C196NU, Microcontroller manual External RC Circuit