Toshiba Release 4.0 Make interval for valid loop pulse detection, Between ring-received events

Models: Release 4.0

1 376
Download 376 pages 3.24 Kb
Page 295
Image 295

..\Server\VoiceBoard<n>

Key

Default

Description

 

 

 

DXBD_MINPDON

2

Minimum Pulse Detection On. Minimum

 

 

make interval for valid loop pulse detection.

DXBD_MINSLOFF

2

Minimum Silence Off. Minimum time for

 

 

silence to be off for valid audio pulse detection.

DXBD_MINSLON

1

Minimum Silence On. Minimum time for

 

 

silence to be on for valid audio pulse detection.

DXBD_MINTIOF

5

Minimum DTI Off. Minimum time required

 

 

between ring-received events.

DXBD_MINTION

5

Minimum DTI On. Minimum time required for

 

 

rings received event.

DXBD_OFFHDLY

50

Off-hook Delay. Period after off-hook, during

 

 

which no events are generated (no DTMF digits

 

 

detected during this time).

DXBD_PAUSETM

200

Pause Time. Delay caused by a comma in the

 

 

dialing string.

DXBD_P_BK

6

Pulse Dial Break. Duration of pulse dial

 

 

off-hook interval.

DXBD_P_IDD

100

Pulse Interdigit Delay. Time between digits in

 

 

pulse dialing.

DXBD_P_MK

4

Pulse Dial Make. Duration of pulse dial

 

 

off-hook interval.

DXBD_R_EDGE

2

Ring Edge. Detection of ring edge:

 

 

1- Beginning of ring

 

 

2 - End of ring

DXBD_R_IRD

80

Inter-ring Delay. Maximum time to wait for the

 

 

next ring (100ms units). Distinguishes between

 

 

calls. Set to 1 for T-1.

DXBD_R_OFF

5

Ring-off interval. Minimum time for ring not to

 

 

be present before qualifying as “not ringing”

 

 

(100 ms units).

DXBD_R_ON

3

Ring-on Interval. Minimum time ring must be

 

 

present to qualify as a ring (100ms units).

DXBD_S_BNC

4

Silence and Non-silence Debounce. Length

 

 

of a changed state before Call Status Transition

 

 

message is generated.

DXBD_TTDATA

10

Duration of DTMF digits for dialing.

APPENDIX A. STRATA CS CONFIGURATION SETTINGS

A-19

BETA DOCUMENT - PRELIMINARY & CONFIDENTIAL

Page 295
Image 295
Toshiba Release 4.0 Make interval for valid loop pulse detection, Minimum DTI Off. Minimum time required, Dialing string