Note: If you are running the Administrator on the Server, click Edit to start the Experimenter. Otherwise, you must run the Experimenter on the Strata CS Server.

4.On the Trunks tab, set the default values for the 24 trunks that will be created in this span. You can then change these values for each trunk individually. See “Entering trunk defaults for a span” below.

5.Click OK to add the span to your configuration.

Using a signaling template

The Robbed Bit T1 Experimenter includes templates that contain Robbed Bit T1 signaling definitions that will be valid in many cases:

nE&MSignaling. Use if your Robbed Bit T1 line supports E&M signaling.

n

n

Local1. Use for a local Robbed Bit T1 line.

Longdistance. Use for a long-distance Robbed Bit T1 line.

To apply a template to a span, click Apply Template on the Signaling tab. Select the template to apply, click Open, and then click OK.

Note: If you have installed the Robbed Bit T1 Experimenter to a directory other than the Strata CS Administrator’s directory, you must look for the template there.

CHAPTER 5. MANAGING TRUNKS AND SPANS

5-15

BETA DOCUMENT - PRELIMINARY & CONFIDENTIAL

Page 75
Image 75
Toshiba Release 4.0 manual Using a signaling template