HKLM\Software\Toshiba\Strata CS\Server\Settings

..\Server\Settings\

AnalogMinTrunkOnhookTime

DWORD value specifying the minimum on-hook time in milliseconds before the trunk will be used for another outbound call.

Default is 3000 milliseconds.

BCPComPort

DWORD value specifying the COM port used to connect to the BCP panel for Watchdog mode. The watchdog signal is transmitted by Strata CS over a serial cable that connects the PC COM port to the “RS-232 Watchdog Signal” port on the connection panel.

Default is 1, indicating that the serial cable is connected to the COM1 port. If you are using the COM1 port for another device, such as a mouse, change this setting to 2 and use the COM2 port.

ConferenceMgr1 and ConferenceMgr2

In an environment that has both Strata and MSI station boards, these values specify whether Strata CS uses all of the available conference managers on the Strata boards before using the conference managers on the MSI boards, or vice versa.

The following case-sensitive codes are used to refer to the MSI and

Strata boards: TvMsi.TerminalMgr and TvStrata.TerminalMgr.

Default settings use the conference managers on the MSI boards first:

ConferenceMgr1 = “TvMsi.TerminalMgr”,

ConferenceMgr2 = “TvStrata.TerminalMgr”

DbCacheInterval

DWORD value specifying the number of minutes between database cache refreshes.

Default is 5 minutes. Setting to zero to turns off cache refreshes.

DisableDevices

See “Disabling Dialogic devices” on page A-13 for details.

Default is 0.

APPENDIX A. STRATA CS CONFIGURATION SETTINGS

A-3

BETA DOCUMENT - PRELIMINARY & CONFIDENTIAL

Page 279
Image 279
Toshiba Release 4.0 manual Server\Settings