XSCF> testsb -v -y -s 00-0
XSCF> showstatus
XSCF> showhardconf
XSCF> showdate
XSCF> setdate -s 102016592013.00
Note- In the case of a d ual power feed, connect the power cords in their original positions by
referringto th ere cord that you made before the start of maintenance.
7. Executethe showstatus command to confirm that the CPU memory unit is
operatingnormally after maintenance.
Ifthere is n o problem, nothing is displayed.
8. Executethe showhardconf command to check the hardware configuration
andthe status of each component.
Confirm that no asterisk (*) is displayed in front of each component.
9. Executethe showdate command to confirm the XSCF time.
Therei s no need to set the time if the NTP server is set to the XSCF. Proceed to
step 11.
10. Ifthe XSCF time is different from the current time, execute the setdate
commandto set the time.
Specifythe ti mei n either of the following formats:
yyyy.MM.DD-hh:mm:ss year.month.day-hour(24-hour clock):minute:second
MMDDhhmmyyyy.ss monthdayhour(24-hour clock) minuteyear.second
Inthe following example, "October 20, 2013 16:59:00" is specified.
11. Startthe system.
For details, see "6.4.1 Starting the system with an XSCF command"or"6.4.2
Starting the system from the operation panel."
12. Closethe rack door.
When the system is configured with a hardware RAID
1. Connect all the power cords to the PSU backplane unit of the chassis
requiringmaintenance.
For details, see "6.5.1 Installing the power cord."