XSCF> showlogs error
XSCF> replacefru
Note- In the case of a d ual power feed, make a note of the locations of the power cords
beforedisconn ecting them to ensure that they are reinstalled correctly.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff the physical partition requiring maintenance.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
27.3.4 Inactive/Cold maintenance1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff the physical partition requiring maintenance.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6. Executethe replacefru command to release the XSCF DUAL control cable
requiringmaintenance from the sys tem.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Remove all the power cords from the PSU backplane unit or power supply
unitof the chassis requiring maintenance.
For details, see "5.5.2 Removing the power cord."
27.3.5 System-stopped maintenance1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013418