XSCF> showlogs error
Date: Oct 20 12:45:31 JST 2012
Code: 00112233-445566778899aabbcc-8899aabbcceeff0011223344
Status: Alarm Occurred: Oct 20 12:45:31.000 JST 2012
FRU: PSU#1,PSU#2
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
Date: Oct 20 15:45:31 JST 2012
Code: 00112233-445566778899aabbcc-8899aabbcceeff0011223344
Status: Warning Occurred: Oct 20 15:45:31.000 JST 2012
FRU: PSU#1,PSU#2
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
Date: Oct 20 17:45:31 JST 2012
Code: 00112233-445566778899aabbcc-8899aabbcceeff0011223344
Status: Alarm Occurred: Oct 20 17:45:31.000 JST 2012
FRU: PSU#1,PSU#2, PSU#3,*
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
Table3-2 Operandsof t he showlogs command and the log to be displayed
Operand Description
error Liststhe error log.
event Liststhe event log.
power Liststhe power log.
env Liststhe temperature history.
monitor Liststhe monitoring message log.
console Liststhe console mess age log.
ipl Lists the I PL message log.
panic Liststhe panic message log.
3.3.5 Checking log information
Executethe showlogs command to check the error log information.
1. Logi n to the XSCF shell.
2. Executethe showlogs command to check the log information.
Thelo g information is listed in the order of date, with the oldest appearing first.
Thefollowing example shows that an Alarm status occurred in PSU#1 and
PSU#2 at 12:45:31 on Oct 20, the Alarm status changed to a Warning status at
15:45:31on the same day, and then the Alarm status further expanded to PSU#1,
PSU#2,a nd PSU#3 at 17:45:31 on the same day.
Table3-2 shows what log information each operand of the showlogs command can
display.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 201338