XSCF> showlogs error
XSCF> testsb -v -y -s 00-0
XSCF> setpparparam -p 0 -s bootscript "setenv auto-boot? false"
XSCF> setpparmode -p 0 -m guestboot=off
XSCF> setpparmode -p 0 -m guestboot=on
normally.
For details, see "3.3.5 Checking log information."
6. Executethe testsb command to confirm that the CPU memory unit requiring
maintenanceis normally recognized.
Fora building block configuration, you do not have to execute the testsb
command. Proceed to step 7.
When you input optional "-y" for the testsb command, the system automatically
answers "y" (yes) in response to an inquiry.
Thefollowing example shows the diagnosis of system board 00-0.
7. Executethe setpparparam command to deactivate the Autoboot function of
thecontrol domain.
Inthe fo llowing example, PPAR-ID 0 is set for Auto boot.
8. Executethe setpparmode command to deactivate the Autoboot function of
theguest domain.
Inthe fo llowing example, PPAR-ID 0 is set for Auto boot.
9. Startthe system.
For details, see "6.4.1 Starting the system with an XSCF command"or"6.4.2
Starting the system from the operation panel."
10. Theok pr ompt appears.
11. Enablethe RAID volume to check the status.
For details, see "14.2.11 Re-enabling a hardware RAID volume" in the Fujitsu
M10/SPARCM10 Systems System Operation and Administration Guide.
12. Executethe setpparmode command to activate the Autoboot function of the
guestdomain.
Inthe fo llowing example, PPAR-ID 0 is set for Auto boot.
13. Executethe showstatus command to confirm that the CPU memory unit is
operatingnormally after maintenance.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 2013156