XSCF> replacefru
Note- In the case of a d ual power feed, make a note of the locations of the power cords
beforedisconn ecting them to ensure that they are reinstalled correctly.
XSCF> showlogs error
Note- When you addor remove CPU memory units, confirm that no error has occurred.
Note- In the case of a d ual power feed, make a note of the locations of the power cords
beforedisconn ecting them to ensure that they are reinstalled correctly.
5. Poweroff the physical partition requiring maintenance.
Fordetails, see "5.3 PoweringOff the Physical Partition Requiring Maintenance."
6.
Executethe replacefru command to release the chassis requiring maintenance
fromthe system.
For details, see "5.1 Releasingan FRU from the System with the replacefru
Command."
7. Removeal l the powercords from the PSU backplane unit of the chassis
requiringmaintenance.
For details, see "5.5.2 Removingthe power cord."
8.4.3 System-stopped maintenance1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checkinglog information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 ConfirmingtheSystem Configuration."
5. Stopthe entire system.
For details, see "5.4 Stoppingthe Entire System."
6. Removeal l the powercords from the PSU backplane unit of the chassis
requiringmaintenance.
For details, see "5.5.2 Removingthe power cord."
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013172