------------------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of model which has FRU to be replaced.
1. BB (4s Building Block Model)
2. XBBOX (XB-BOX Model)
------------------------------------------------------------------------------
Select [1,2|c:cancel] :c
Note- When you incorporate a system board with the addboard command, the target system
boardis incorpo rated into the physical partition after its hardware diagnosis. Therefore, it
maytake tim e for the command execution to complete.
XSCF> addboard -c configure -p 0 01-0
PSB#01-0 will be configured into PPAR-ID 0. Continue?[y|n] :y
Start connecting PSB to PPAR. [3600sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240.....
270.....300.....330.....360.....390.....420.....450.....480.....510.....
540.....570.....600.....630.....660.....690.....720.....750.....780.....
810.....840.....870.....900.....930.....960.....end
Connected PSB to PPAR.
Start configuring PSB to Logical Domains (LDoms) Manager. [1800sec]
0.....end
Configured PSB to Logical Domains (LDoms) Manager.
Operation has completed.
6.2 Incorporating a Chassis into a PhysicalPartitionThissectio n describes the procedure for incorporating a chassis into a physical
partition by using dynamic reconfiguration (DR) after FRU maintenance.
1. LogintotheXSCFshell.
2. Executethe addboard command to incorporate the target chassis into the
physicalpartiti on.
Inresponse to the confirmation message, enter "y".
Inthe following example, PSB 01-0 is incorporated into PPAR-ID 0.
3. Executethe showresult command to check the end status of the addboard
commandthat was just executed.
Thefoll owing example shows that "0" is returned as the end status and the
execution of the addboard command has been completed successfully.
Chapter6 Understandingthe Preparations for Restoring the System 71