Label Disk name Vendor Product Vers
-------- ---------------------- -------- -------------- ----
HDD_0 c0t50000393D8289180d0 TOSHIBA MBF2600RC 3706 <-- (1)
Physical path
--------------------------------
0: /pci@8000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w50000393D8289180,0<--(2)
* LSB#0
HDD_1 c0t50000393D82891D0d0 TOSHIBA MBF2600RC 3706 <-- (3)
Physical path
--------------------------------
0: /pci@8000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w50000393D82891D0,0<--(4)
* LSB#0
Table12-1 Diskslot number
LSBnumber Device path
LSB#0 /pci@8000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#1 /pci@8800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#2 /pci@9000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#3 /pci@9800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#4 /pci@a000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#5 /pci@a800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#6 /pci@b000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#7 /pci@b800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#8 /pci@c000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#9 /pci@c800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#10 /pci@d000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#11 /pci@d800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#12 /pci@e000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#13 /pci@e800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#14 /pci@f000/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
LSB#15 /pci@f800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@wWWN,0
Devicep aths differ depending on the system configuration.
Table12-1 listsexamples of the device paths of logical system boards in SPARC
M10systems.
Thistable can be used for mapping of the device paths of internal disk drives
andthe l ogical system board numbers. The letters "WWN" in the table represents
theWW N assigned to the disk.
2. Executethe showboards command to confirm the BB-ID of the chassis in
whichthe disk requiring maintenance is mounted.
Identifyth e BB-ID from the LSB number confirmed in step 1. The BB-ID of the
Chapter12 Maintainingthe Internal Disks 225