XSCF> poweron -p 0
Note- Fo r a building block configuration, check the XSCF STANDBY LEDs of all the chassis
constitutingthe system.
Note- Fo r a building block configuration, switch the mode switches of the master chassis
andthose chassis wh oseX SCFs are in the standby state.
XSCF> showstatus
XSCF> showhardconf
SPARC M10-4S;
+ Serial:2081229003; Operator_Panel_Switch:Service;
+ System_Power:On; System_Phase:Cabinet Power On;
Partition#0 PPAR_Status:Running;
BB#00 Status:Normal; Role:Master; Ver:2050h; Serial:2081229003;
+ FRU-Part-Number:CA07361-D202 A0 ;
+ Power_Supply_System: ;
+ Memory_Size:320 GB;
Enterthe P PAR-ID you noted in advance by using the showboards command.
Inthe fo llowing example, PPAR-ID 0 is specified.
6.4 Starting the Entire System
Thissection describes the procedure for starting the entire system.
Thesystem can be started in either of the following two ways:
Starting the system with an XSCF command
Starting the system from the operation panel
1. Check that the XSCF STANDBY LED on the operation panel is on.
2. Logi n to the XSCF shell.
3. Switch the mode switch on the operation panel to Locked mode.
For details, see "2.2.2 Control function of the operation panel."
4. Executethe showstatus command to confirm that there is no problem with
theFRU after the completion of maintenance.
Ifthere is n o problem, nothing is displayed.
5. Executethe showhardconf command to check the hardware configuration
andthe status of each component.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 201374