XSCF> replacefru
XSCF> showlogs error
XSCF> replacefru
Note- Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
beforedisconne cting them to ensure that they are reinstalled correctly.
Fordetails, see "5.3 PoweringOff the Physical Partition Requiring Maintenance."
6. Executethe replacefru command to release the XSCF unit requiring
maintenancefrom the system.
For details, see "5.1 Releasingan FRU from the System with the replacefru
Command."
17.3.3 System-stopped maintenance
1. Open the rack door.
2. LogintotheXSCFshell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checkinglog information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 ConfirmingtheSystem Configuration."
5. Poweroff all the physical partiti ons.
Fordetails, see "5.3 PoweringOff the Physical Partition Requiring Maintenance."
6. Executethe replacefru command to release the XSCF unit requiring
maintenancefrom the system.
For details, see "5.1 Releasingan FRU from the System with the replacefru
Command."
7. Remove all the power cords from the power supply unit of the crossba r box
requiringmaintenance.
For details, see "5.5.2 Removingthe power cord."
Chapter17 MaintainingtheXSCF Unit of the Crossbar Box 311