XSCF> diagxbu -y -b 00 -t 01
XSCF> showlogs error
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3. Execute the diagxbu command to diagnose the crossbar cables.
Diagnosisis performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physicalpartition into which the chassis is incorporated is powered off.
Theexa mple below specifies the following:
00:BB-ID ofthe chassist o start the diagnosis
01:BB-ID o ft he destination where the chassis to start the diagnosis is connected
(You can specify one or more of these.)
Tospecif y multiple connection destination BB-IDs, enter a command like
"diagxbu -y -b 00 -t 01 -t 02".
4. Executethe showlogs command to confirm that the system is operating
normally.
For details, see "3.3.5 Checking log information."
5. Poweron all the physical partitions.
Fordetails, see "6.3 Powering On the PhysicalPartition Requiring Maintenance."
6. Closethe rack door.
Chapter25 Maintainingthe Crossbar Cables (Optical) 399