#ldm stop iodomain
#ldm remove-io /BB1/PCI0 iodomain
XSCF> replacefru
Note- Inactive/ hot maintenance can be performed only for a building block configuration.
Fora single -chassis configuration, system-stopped maintenance should be performe d.
e. Releasefrom the physical partiti on thechassis in which the PCIe card
requiringmaintenance is mounted.
For details, see "5.2 Releasing a Chassis from the Physical Partition."
4.
Executethe replacefru command to release the chassis requiring maintenance
fromthe system.
For details, see "5.1 Releasingan FRU from the System with the replace fru
Command."
13.4.3 Inactive/Hot maintenance
1. Open the rack door.
2. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
3. Poweroff the physical partition requiring maintenance.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
13.4.4 System-stopped maintenance
TheP CIe cards can be removed/installed while the input power to the chassis is on
(power cord is connected). System-stopped maintenance is also described as
maintenanceperformed while the power cord remains connected.
1. Open the rack door.
2. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
3. Stopthe entire system.
For details, see "5.4 Stoppingthe Entire System."
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 2013252