Note- Che ck that the power supply unit is fully inserted and that the lever is fixed.
XSCF> showstatus
XSCF> showhardconf
18.6 Restoring the SystemThissectio n describes the procedure for restoring the system after installing a power
supply unit. The restoration procedure differs depending on the maintenance type as
follows:
■Active/Hot maintenance
■Inactive/Hot maintenance
■System-stopped maintenance
18.6.1 Active/Hot maintenance
1. Connectthe power cords to the power supply unit requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2. Confirmthat theLED (green) of the power supply unit is on.
3. Returnto the operation of theXSCF firmware replacefru command to confirm
thatthe power supply unit has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
4. Executethe showstatus command to confirm that the power supply unit is
operatingnormally after thecompletion of maintenance.
5. Executethe showhardconf command to check the hardware configuration
andthe status of each component.
6. Closethe rack door.
18.6.2 Inactive/Hot maintenance
1. Connectthe power cords to the power supply unit requiring maintenance.
For details, see "6.5.1 Installing the power cord."
2. Confirmthat theLED (green) of the power supply unit is on.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013324