XSCF> diagxbu -y -b 00 -t 01
XSCF> showlogs error
Note- In the case of a d ual power feed, connect the power cords in their original positions by
referringto th ere cord that you made before the start of maintenance.
3. Executethe diagxbu command to diagnose the crossbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physical partition into which the chassis is incorporated is powered off.
Theex ample below specifies the following:
00:BB-ID ofthe c hassis to start the diagnosis
01:BB-ID ofthe destin ation where the chassis to start the diagnosis is connected
(Youcan specify one or more of these.)
To specify multiple connection destination BB-IDs, enter a command like
"diagxbu-y -b 00 -t 01 -t 02".
4. Executethe showlogs command to confirm that the system is operating
normally.
For details, see "3.3.5 Checking log information."
5. Poweron the physical partition requiring maintenance.
Fordetails, see "6.3 Powering On the Ph ysical Partition Requiring Maintenance."
6. Closethe rack door.
14.6.3 System-stopped maintenance1. Connectall the power cords to the PSU backplane unit.
For details, see "6.5.1 Installing the power cord."
2. Returnto the operation of theXSCF firmware replacefru command to confirm
thatthe chassis has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
Fora single-chassis configuration, you do not have to incorporate the chassis.
Proceedto step 5.
3. Executethe diagxbu command to diagnose the crossbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physical partition into which the chassis is incorporated is powered off.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013278