Please execute the following steps:
1) Confirm the XSCF STANDBY LED of BB#0 is not lit.
2) Turn off the breaker of BB#0.
3) Remove BB#0.
4) Execute either the following:
4-1) After the exchanged device is connected with the system,
turn on the breaker of BB#0, and please select 'finish'.
4-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :f
Chapter 6Understanding the Preparations forRestoring the System
Thisch apter describes the procedures required to restore the system after component
maintenance. See this chapter, as required, when performing maintenance on each
componentdescribed in Chapter 7 onwards.
Incorporating an FRU into the System with the replacefru Command
Incorporating a Chassis into a Physical Partition
Powering On the Physical Partition Requiring Maintenance
Starting the Entire System
Restoring the Chassis
6.1 Incorporating an FRU into the Systemwith the replacefru Command
Thissectio n describes the procedure for incorporating a Field Replaceable Unit (FRU)
intot he system after maintenance. To do this, resume the replacefru command,
whichis running, to incorporate the FRU into the system.
1. Aftercompleting maintenance of the target FRU, return to the operation of the
replacefrucommand of the XSCF firmware, and enter "f".
Thefoll owing is displayed. Wait until the processing is complete.
69