XSCF> showlogs error
XSCF> replacefru
Note- Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
beforedisconne cting them to ensure that they are reinstalled correctly.
XSCF> showlogs error
XSCF> replacefru
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff the physical parti tion requiring maintenance.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to release the chassis requiring maintenance
fromthe system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Remove all the power cords from the PSU backplane unit of the chassis
requiringmaintenance.
For details, see "5.5.2 Removing the power cord."
9.3.3 System-stopped maintenance1. Open the rack door.
2. LogintotheXSCFshell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Stopthe entire system.
For details, see "5.4 Stopping the Entire System."
6.
Execute the replacefru command to release the chassis requiring maintenance
fromthe system.
Chapter9 Maintainingthe Crossbar Units 183