XSCF> replacefru
XSCF> showlogs error
XSCF> replacefru
Note- Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
beforedisconne cting them to ensure that they are reinstalled correctly.
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff the physical parti tion requiring maintenance.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Executethe replacefru command to release the fan unit requiring maintenance
fromthe system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
19.3.3 System-stopped maintenance1. Open the rack door.
2. LogintotheXSCFshell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff all the physical partiti ons.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Executethe replacefru command to release the fan unit requiring maintenance
fromthe system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Remove all the power cords from the power supply unit of the crossba r box
requiringmaintenance.
For details, see "5.5.2 Removing the power cord."
Chapter19 Maintaining theFan Uni tsof the Crossbar Box 331