Caution - To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
Note- Active/hot maintenance is supported only for a redundant configuration.
XSCF> showlogs error
XSCF> replacefru
of a power supply unit. The preparation procedure differs depending on the
maintenancetype as follows:
Active/Hot maintenance
Inactive/Hot maintenance
System-stopped maintenance
18.3.1 Active/Hot maintenance
1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Executethe replacefru command to release the power supply unit requiring
maintenancefrom the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
6. Remove the powercord from the power supply unit requiring maintenance.
For details, see "5.5.2 Removing the power cord."
18.3.2 Inactive/Hot maintenance
1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 2013320