Caution - Before you handle any components, wear a wrist strap to ground any static
electricity.If y ou perform this procedure without a wrist strap, individual
componentsor the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
Note- Ma ke a note of the positions of the crossbar cables (optical) before disconnecting them
toensure that theyare reinst alled correctly.
A
A
1. Removeal l crossbar cables (optical) connected to the crossbar unit requiring
maintenance.
For details, see "25.4 Removinga Crossbar Cable (Optical)."
2. Loosenthe two screws (A in the figure) on the right and left sides and lower
thelev ers to release thecrossbar unit.
Figure16-2 Positions of screws and levers
3. Holdthe le vers and partially pull out the crossbar unit.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013302