Caution - To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
XSCF> showlogs error
XSCF> switchscf -t Standby
26.3 Enabling the Removal of an XSCF BBControl Cable
Thissectio n describes preparations that must be completed prior to removing the
XSCFBB control cables. The preparation procedure differs dependingon the
maintenancetype as follows:
■Active/Hot maintenance
■Active/Cold maintenance
■Inactive/Hot maintenance
■Inactive/Cold maintenance
■System-stopped maintenance
26.3.1 Active/Hot maintenance
1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Execute the switchscf command to switch the master XSCF to a standby
XSCF.
Perform this when the chassis requiring maintenance is operating as a master
chassis.
6.
Executethe replacefru command to release the chassis requiring maintenance
fromthe system.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013404