------------------------Ommitted------------------------
PCI#0 Status:Normal; Name_Property:pci;
+ Vendor-ID:108e; Device-ID:9020;
+ Subsystem_Vendor-ID:0000; Subsystem-ID:0000;
+ Model:;
+ Connection:7001;
PCIBOX#7001; Status:Normal; Ver:1110h; Serial:2121237001;
+ FRU-Part-Number:;
IOB Status:Normal; Serial:PP123403JE ;
+ FRU-Part-Number:CA20365-B66X 008AG ;
LINKBOARD Status:Normal; Serial:PP1234026P ;
+ FRU-Part-Number:CA20365-B60X 001AA ;
PCI#1 Name_Property:ethernet;
+ Vendor-ID:1077; Device-ID:8000;
+ Subsystem_Vendor-ID:1077; Subsystem-ID:017e;
+ Model:;
------------------------Ommitted-----------------------
XSCF> poweron -a
PPAR-IDs to power on:00,01
Continue? [y|n] :y
00 : Powering on
01 : Powering on
For details, see "3.3.3 Checkingthe statu so f a component."
6. Start theenti re system.
For details, see "6.4.1 Startingthe system with a n XSCF command"or"6.4.2
Starting the system from the operation panel."
Aftera sh ort while, the following processes are performed.
TheP OWER LED on the operation panel will be turned on.
Thepo wer-on self-test (POST; self diagnosis when powering on) will be
executed.
Then,the sy stem starts up. For details, see "6.1 Startingth e System" in the
FujitsuM10/SPARC M10 Systems System Operation and Administration Guide.
6.4.1 Starting the system with an XSCF command
1. Execute the poweron command.
Inresponse to the confirmation message, enter "y".
6.4.2 Starting the system from the operation panel
1. Pressthe power switch on the operation panel for 1 second or more (less
Chapter6 Understandingthe Preparations for Restoring the System 75