XSCF> showlogs error
XSCF> replacefru
XSCF> showlogs error
XSCF> replacefru
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff the physical parti tion requiring maintenance.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6. Executethe replacefru command to release the power supply unit requiring
maintenancefrom the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Removethe power cord from the power supply unit requiring maintenance.
For details, see "5.5.2 Removing the power cord."
18.3.3 System-stopped maintenance
1. Open the rack door.
2. LogintotheXSCFshell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff all the physical partiti ons.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6. Executethe replacefru command to release the power supply unit requiring
maintenancefrom the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Remove all the power cords from the power supply unit of the crossba r box
Chapter18 Maintainingthe Power Supply Uni tsof the Crossbar Box 321