Caution- Toco mpletely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
XSCF> showlogs error
XSCF> replacefru
Don ot bend the crossbar cables (optical) unduly. If you unduly bend a crossbar
cable (optical), it may be damaged. Ensure that the static/dynamic bending radius
ofthe c rossbar cable (optical) is no less than 35 mm (1.4 in.).
25.3 Enabling the Removal of a CrossbarCable (Optical)
Thissectio n describes the preparations that must be completed prior to removing a
crossbarcable (optical). The preparation procedure differs depending on the
maintenance type as follows:
Inactive/Cold maintenance
System-stopped maintenance

25.3.1 Inactive/Cold maintenance

1. Open the rack door.
2. LogintotheXSCFshell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff the physical parti tion requiring maintenance.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6. Executethe replacefru command to release the SPARC M10-4S requiring
maintenancefrom the system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
Chapter25 Maintainingthe Crossbar Cables (Optical) 393