XSCF> diagxbu -y -b 00 -t 01
XSCF> showlogs error
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physical partition into which the chassis is incorporated is powered off.
Theex ample below specifies the following:
00:BB-ID ofthe c hassis to start the diagnosis
01:BB-ID ofthe destin ation where the chassis to start the diagnosis is connected
(Youcan specify one or more of these.)
To specify multiple connection destination BB-IDs, enter a command like
"diagxbu-y -b 00 -t 01 -t 02".
4. Executethe showlogs command to confirm that the system is operating
normally.
For details, see "3.3.5 Checking log information."
5. Poweron the physical partition requiring maintenance.
Fordetails, see "6.3 Powering On the Ph ysical Partition Requiring Maintenance."
6. Closethe rack door.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 2013306