XSCF> showstatus
XSCF> showhardconf
Note- In the case of a d ual power feed, connect the power cords in their original positions by
referringto th ere cord that you made before the start of maintenance.
XSCF> showstatus
XSCF> showhardconf
normallyafter thecompletion of maintenance.
3. Executethe showhardconf command to check the hardware configuration
andthe status of each component.
4. Closethe rack door.
27.6.2 Active/Cold maintenance
1. Connectall the power cords to the PSU backplane unit or power supply unit
ofthe chassis requir ing maintenance.
For details, see "6.5.1 Installing the power cord."
2. Returnto the operation of theXSCF firmware replacefru command to confirm
thatthe XSCF DUAL control cable has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
3. Executethe showstatus command to confirm that the XSCF DUAL control
cableis operating normally af ter the completion of maintenance.
4. Executethe showhardconf command to check the hardware configuration
andthe status of each component.
5. Closethe rack door.
27.6.3 Inactive/Hot maintenance
1. Returnto the operation of theXSCF firmware replacefru command to confirm
thatthe XSCF DUAL control cable has been incorporated into the system.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 2013422