Note- Place the re moved XSCF unit on a grounded antistatic ESD mat.
Note - When mountinga XSCF unit, check the connectors on both of the chassis and
XSCF unit beforehand to confirm that no pin is bent and all the pins are neatly
arranged in lines. If an XSCF unit is mounted with a bent pin in a connector, the
chassis or XSCF unit may be damaged. Also, carefully proceed with the work to
prevent any pin from being bent.
Figure17-3 Pulling out the XSCF unit
4. Support the XSCF unit from below with one hand and then remove it careful ly.
17.5 Installing the XSCF Unit
Thissectio n describes the procedure for installing the XSCF unit.
1. Carefully insert the XSCF unit into the chassis.
2. Raisethe right and left lev ers andthen tighten the two screws.
3. Reconnect all the cables to the XSCF unit.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 2013314