XSCF> showstatus
XSCF> showhardconf
Note- In the case of a d ual power feed, connect the power cords in their original positions by
referringto th ere cord that you made before the start of maintenance.
19.6.1 Active/Hot maintenance1. Returnto the operation of theXSCF firmware replacefru command to confirm
thatthe fan unit has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2. Executethe showstatus command to confirm that there is no problem with
thefan unit afte r the completion of maintenance.
3. Executethe showhardconf command to check the hardware configuration
andthe status of each component.
4. Closethe rack door.
19.6.2 Inactive/Hot maintenance1. Returnto the operation of theXSCF firmware replacefru command to confirm
thatthe fan unit has been incorporated into the system.
For details, see "6.1 Incorporating an FRU into the System with the replacefru
Command."
2. Poweron the physical partition requiring maintenance.
Fordetails, see "6.3 Powering On the Ph ysical Partition Requiring Maintenance."
3. Closethe rack door.
19.6.3 System-stopped maintenance1. Connect all the power cords to the power supply unit of the crossbar box
requiringmaintenance.
For details, see "6.5.1 Installing the power cord."
2. Returnto the operation of theXSCF firmware replacefru command to confirm
thatthe fan unit has been incorporated into the system.
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013334