#cfgadm -a
Ap_Id Type Receptacle Occupant Condition
BB#0-PCI#0 pci-pci/hp connected configured ok
#cfgadm -c unconfigure Ap_Id
#cfgadm -c disconnect Ap_Id
#cfgadm -a
Ap_Id Type Receptacle Occupant Condition
BB#0-PCI#0 pci-pci/hp disconnected unconfigured ok
#cfgadm -x led=attn,mode=blink Ap_Id
Note- To performactive/h ot maintenance without using PHP, use DR of the system bo ard
onthe physical partition. For information on the versions of XCP and Oracle VM Server for
SPARC/SRUthat support DR, see the latest Product Notes.
Note- Active/h ot maintenance without using PHP can be performed only for a building
blockconfiguration.
8. Executethe cfgadm -c command to release the PCIe card requiring
maintenancefrom the logical domain.
Enterthe Ap_ID you noted in advance.
9. Executethe cfgadm -c command to stop the power supply to the PCIe card
requiringmaintenance.
Enterthe Ap_ID you noted in advance.
10. Executethe cfgadm -a command to confirm the status of the PCIe card again.
Inthe following example, [Receptacle] and [Occupant] contain "disconnected"
and"unconfigured", respectively, which indicates that the PCIe card requiring
maintenance is released from the logical domain.
11. Executethe cfgadm -x command to cause the ATTENTION LED on the PCIe
cardcassette requiring maintenance to blink.
Enterthe Ap_ID you noted in advance.
13.4.2 Active/Hot maintenance (with DR)1. Open the rack door.
2. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013250