XSCF> replacefru
Note- Inactive /cold maintenance can be performed only for a building block configuration.
Theinactive/cold maintenancepr ocedure for a single-chassis configuration is the same as
thatfor sto pping the system.
XSCF> showlogs error
XSCF> replacefru
Note- Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
beforedisconne cting them to ensure that they are reinstalled correctly.
5. Poweroff the physical parti tion requiring maintenance.
Fordetails, see "5.3 PoweringOff the Physical Partition Requiring Maintenance."
6. Executethe replacefru command to release the power supply unit requiring
maintenancefrom the system.
For details, see "5.1 Releasingan FRU from the System with the replacefru
Command."
10.3.4 Inactive/Cold maintenance
1. Open the rack door.
2. LogintotheXSCFshell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checkinglog information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 ConfirmingtheSystem Configuration."
5. Poweroff the physical parti tion requiring maintenance.
Fordetails, see "5.3 PoweringOff the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to release the chassis requiring maintenance
fromthe system.
For details, see "5.1 Releasingan FRU from the System with the replacefru
Command."
7. Remove all the power cords from the PSU backplane unit of the chassis
requiringmaintenance.
For details, see "5.5.2 Removingthe power cord."
Chapter10 MaintainingthePow er Supply Units 197