XSCF> showlogs error
XSCF> replacefru
Note- In the case of a d ual power feed, make a note of the locations of the power cords
beforedisconn ecting them to ensure that they are reinstalled correctly.

10.3.5 System-stopped maintenance

1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Stopthe entire system.
For details, see "5.4 Stopping the Entire System."
6.
Executethe replacefru command to release the chassis requiring maintenance
fromthe system.
For a single-chassis configuration, you do not have to release the chassis.
Proceedto step 7.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Removeal l the powercords from the PSU backplane unit of the chassis
requiringmaintenance.
For details, see "5.5.2 Removing the power cord."
10.4 Removing a Power Supply Unit
Thissection describes the procedure for removing a power supply unit. Enable the
removal of the power supply unit before attempting to remove it. For details, see
"10.3 Enablingthe Removal of a Power Supply Unit."
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 2013198