XSCF> showlogs error
XSCF> replacefru
Note- Inthecaseofadualpowerfeed,makeanoteofthelocationsofthepowercords
beforedisconne cting them to ensure that they are reinstalled correctly.
Caution- Before you handle any components, wear a wrist strap to ground any static
electricity.I fy ou perform this procedure without a wrist strap, individual
componentsor the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Poweroff all the physical partiti ons.
Fordetails, see "5.3 Powering Off the Physical Partition Requiring Maintenance."
6.
Execute the replacefru command to release the chassis requiring maintenance
fromthe system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Remove all the power cords from the PSU backplane unit or power supply
unitof the chassis requiring maintenance.
For details, see "5.5.2 Removing the power cord."
26.4 Removing an XSCF BB Control CableThissection describes the procedure for removing the XSCF BB control cables.
Enable removal of the XSCF BB control cables before attempting to remove them. For
details,see "26.3 Enabling the Removal of an XSCF BB Control Cable."
1. Removethe XSCF BB control cable from the SPARC M10-4S or the crossbar
box.
Pullo ut an XSCF BB control cable while pushing the lock release buttons (A in
thefigure) on the both sides of the cable.
Chapter26 Maintainingthe XSCF BB Control C ables 407