XSCF> showlogs error
XSCF> replacefru
Note- In the case of a d ual power feed, make a note of the locations of the power cords
beforedisconn ecting them to ensure that they are reinstalled correctly.
Caution - Before you handle any components, wear a wrist strap to ground any static
electricity.If y ou perform this procedure without a wrist strap, individual
componentsor the overall system may be damaged. For details, see "1.5 Notes
Regarding Static Electricity."
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5. Stopthe entire system.
For details, see "5.4 Stopping the Entire System."
6.
Executethe replacefru command to release the chassis requiring maintenance
fromthe system.
For a single-chassis configuration, you do not have to release the chassis.
Proceedto step 7.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
7. Removeal l the powercords from the PSU backplane unit of the chassis
requiringmaintenance.
For details, see "5.5.2 Removing the power cord."
15.4 Removing the Operation PanelThissection describes the procedure for removing the operation panel.
Enable the removal of the operation panel before attempting to remove it. For details,
see"15.3 Enabling the Removal of the Operation Panel."
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・December 2013286