Caution - To completely shut down the system, all the power cords must be
removed. If the power cords are not removed, an electrical failure may occur.
XSCF> showlogs error
XSCF> replacefru
XSCF> showlogs error
fanunit. The preparation procedure differs depending on the maintenance type as
follows:
Active/Hot maintenance
Inactive/Hot maintenance
System-stopped maintenance
19.3.1 Active/Hot maintenance
1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
4. Confirmthe hardware and software configurations.
For details, see "4.2 Confirmingthe System Configuration."
5.
Executethe replacefru command to release the fan unit requiring maintenance
fromthe system.
For details, see "5.1 Releasing an FRU from the System with the replacefru
Command."
19.3.2 Inactive/Hot maintenance
1. Open the rack door.
2. Logi n to the XSCF shell.
3. Executethe showlogs command to identify the component requiring
maintenance.
For details, see "3.3.5 Checking log information."
FujitsuM10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual December 2013330